Case study·North Toronto·Outdoor living

North Toronto Cabana
A backyard that does everything, on the existing 200 A service

An insulated cabana with a full kitchen and washroom, a louvered pergola, a gas fireplace, a water feature and three 4.5 kW infrared heaters. On paper it needed a bigger service. Two years of the home's own data said it didn't, so one cable from the house now runs the whole yard.

Plan My Outdoor Space →Prefer to talk? Call (416) 670-4030

Fixed quote within 1 to 2 business days, sized on your own data.

Backyard cabana pergola with a louvered roof, gas fireplace and lounge seating, North Toronto
Louvered pergola and gas fireplace
165 A
New equipment, added up on paper
90 A
The house's real peak in two years
100 A
Cabana panel, 20+ circuits, no service upgrade
1 trench
50 m of feeder, shared with gas and water
Watch the build

The whole cabana, in three minutes

Backyard cabana at night with a lit fireplace and pergola, North Toronto
3:10

Filmed on site as each part went in: the power, the trench, the panel, the heaters, the fireplace, the lights and the fountain.

  1. 0:00Where the power comes from
  2. 0:26One trench for gas, water and power
  3. 0:37The cabana panel
  4. 1:50Recessed heaters, and the fan they need
  5. 2:02Pergola heaters under a thermal camera
  6. 2:28The gas fireplace on a GFI breaker
  7. 2:45Lights made for a slatted ceiling
  8. 2:52The fountain

Design: Bosque Landscape · Built by Parkscape · Film: Limeback Media · Heaters: Bromic · Electrical: Energable

Finished

North Toronto Cabana

North Toronto Cabana, photo 1
North Toronto Cabana, photo 2
North Toronto Cabana, photo 3
North Toronto Cabana, photo 4
North Toronto Cabana, photo 5
The project

A small building at the end of the garden

The landscape contractor designed the whole outdoor build, and had the electrical in the plan from day one. The cabana is really a small building: insulated walls, glass doors, its own kitchen, washroom, hot water and network. Outside it, a louvered-roof pergola, a gas fireplace, a fountain and landscape lighting.

Everything had to work from a phone, and none of the wiring could show. That meant every decision was made before the slat ceiling, the stone and the paving went on.

The systems

Six systems, one cabana panel

What each one draws, how it is wired, and the detail that makes it work. The bars compare each load with the cabana's 100 A panel.

Infrared heaters, North Toronto CabanaInfrared heaters

Three Bromic Platinum Smart-Heat Electric, 4.5 kW each

56 A at full output
How it is wired
Two recessed flush into the cabana ceiling, one in the pergola beam. Each on its own 30 A circuit and an app-controlled dimmer.
The detail
The ceiling recess kits have their own cooling fans, so they get a separate, always-on circuit.
Cabana kitchen, North Toronto CabanaCabana kitchen

Clear ice maker, fridge drawers, dishwasher drawer, counters

about 30 A in use
How it is wired
A dedicated circuit for every appliance, two 20 A counter circuits and one in the island, so the blender and kettle can run together.
The detail
A cabana kitchen gets used exactly like the one in the house.
Louvered pergola, North Toronto CabanaLouvered pergola

Motorized louvered roof

about 5 A
How it is wired
The roof motor and its controller on their own circuit, with the controls kept out of the weather.
The detail
Motors and control hubs get constant power, never switched with a load.
Gas fireplace, North Toronto CabanaGas fireplace

Electric ignition and blower

about 2 A
How it is wired
Power is only for ignition and the blower: one receptacle inside the stone, fed by its own buried cable.
The detail
Ground-fault protection sits on a breaker in the cabana panel, where the reset is easy to find.
Water feature, North Toronto CabanaWater feature

Submersible fountain pump

about 5 A
How it is wired
Its own ground-fault protected circuit, a weatherproof switch and a service receptacle at the feature.
The detail
Water and power side by side is the one place nobody improvises.
Lighting and network, North Toronto CabanaLighting and network

Ceiling downlights, landscape lighting, TV and Cat6

about 6 A
How it is wired
Six slim black downlights on a dimmer in the slat ceiling, a circuit for the landscape lighting transformer, and a wired network run to the TV.
The detail
Wi-Fi in a backyard is never as good as you hope, so the cabana gets a cable.
On paper vs real life

165 A of new load, and no service upgrade

We pulled 17,400 hourly readings from Toronto Hydro, two full years, and ran the Code calculation before anything was designed.

On paper: the house plus every new nameplateThe house's peak plus all the cabana equipment at once
255 A
Service limit, 200 A
The existing service200 A at 240 V
200 A
The house's real peak in 24 monthsA heat wave, air conditioning running, by the Code method
90 A
Realistic peak with the cabanaHeaters on dimmers, seasonal use
130 A
Heaters run in the cold, air conditioning in the heat, and the two never meet. On paper the backyard needed a 400 A service and a utility application. Two years of the home's own meter data showed it never used more than half of the 200 A it already had.
How it responds

Summer and winter never meet

Pick a season, then try the heater dimmers.

A cold evening outside, heaters on

Slide it. Most cool evenings are comfortable at 40 to 50 percent.
160 A200 A
HouseCabana kitchen, pump, lightsHeaters160 A continuous line
Estimated total
125 A
Service left
75 A

Estimates from the load assessment, rounded.

How it comes together

One cable leaves the house, and everything hangs off it

The house
Existing 200 A panel
Reworked to make room for a new 100 A breaker. No service upgrade.
Underground
50 m of armoured copper feeder
Two feet down in sand with warning tape above, sharing one trench with the gas and water at their own depths.
The cabana
100 A panel, 20+ circuits
Every load has its own breaker, a few steps from where it is used.

Tap a system to see how it is wired.

Three 30 A heater circuits, plus a fan circuit

  • Two ceiling heaters on a two-channel dimmer, the pergola heater on a one-channel dimmer
  • Both dimmers in one dry equipment cavity, paired to a phone app
  • A separate always-on circuit for the ceiling recess fans
The fan circuit is in the wiring diagram, not the brochure. It decides whether a ceiling like this lasts.
Things nobody will see

The best electrical work disappears

All of this was built, inspected and then covered by the finishes. You can stand in the yard today and not find a single wire.

One trench

One trench

50 m of armoured copper in a sand bed, inspected, then buried under the paving for good.

The way out of the house

The way out of the house

A weatherproof box on the foundation and a cored sleeve, sealed against weather outside and fire inside.

The heater dimmers

The heater dimmers

Both controllers in one dry, ventilated cavity, with clearance around their heat sinks.

The cabana panel

The cabana panel

Every circuit labelled, with the ground-fault breakers where the owner will look for them.

Planning an outdoor space?

The electrical list, in order

  1. Load assessment first. It decides whether you run a feeder or apply for a new service, and everything else waits on that answer.
  2. A real panel in the cabana. Every load gets its own breaker a few steps away, with room to grow.
  3. Trench once. Electrical, gas and water in one coordinated trench, planned with the landscape contractor before the first shovel.
  4. Heaters on dimmers, not switches. Comfort and load management in one device.
  5. Constant power for fans and controllers. Recess kits, roof motors and hubs are never switched with the load.
  6. Ground-fault protection you can reach. If a receptacle ends up behind a finish, protect it at the breaker.
  7. A wired network to the cabana. Backyard Wi-Fi is never as good as you hope.
  8. Leave spare circuits and a spare sleeve. The next idea always comes.
The process

How a project like this comes together

  1. 1
    Site walk and plans. We walk the yard with the landscape drawings and list every load, drain, footing and heated zone.
  2. 2
    Load assessment. Two years of the home's utility data and the Code calculation confirm the service, before anything is designed.
  3. 3
    Route and trench layout. Feeder size, depths and sleeves set against the landscape plan, handed to the landscape crew to dig once.
  4. 4
    Feeder, panel and rough-in. Cable in, trench inspected before backfill, then every circuit roughed in before the finishes close.
  5. 5
    Connections and controls. Appliances, heaters and dimmers connected, apps paired and every circuit labelled.
  6. 6
    Inspection and handover. Final Electrical Safety Authority inspection, then a walkthrough of the controls with the owners.

Planning a cabana, pool house or outdoor kitchen?

Find out what your service can carry before you design

Send the address and your plans. We review your hourly data, check the service and send a fixed quote within 1 to 2 business days.

Get My Outdoor Quote →
Straight Answers

Outdoor Cabana Questions

The kind we would give before you commit a dollar of capital. Tap a question.

Does a backyard cabana with heaters and a kitchen need a service upgrade?
Often not. This cabana added about 165 A of equipment to a 200 A house. Two years of utility data showed the house peaked at 90 A, so a 100 A cabana panel fed from the existing service was enough. A load assessment on the home's own data answers it before anything is designed.
How do you power an outdoor cabana or pool house?
With a subpanel. One feeder from the house panel to a panel in the cabana, then a breaker for every load a few steps away. It costs little more than a handful of long circuits and leaves room to grow.
How much power do electric patio heaters use?
A lot, at full output. Each 4.5 kW Bromic heater draws about 19 A on its own 30 A circuit, so three is about 56 A. On dimmers they usually run at 40 to 50 percent, which is more comfortable and keeps the load down.
How deep does an outdoor feeder cable need to be buried in Ontario?
It depends on the cable and the location. Here the armoured cable runs at least 24 inches down in a sand bed with warning tape above it, sharing the trench with gas and water at their own depths, and it was inspected before backfill.
Should outdoor heaters be on switches or dimmers?
Dimmers. A 4.5 kW heater on a switch is full blast or off. A dimmer gives comfortable heat at partial output and is also the simplest form of load management.
Who coordinates the electrical with the landscape contractor?
Both, from the first drawing. This project worked because the landscape plan showed drains, footings and the heated slab before the trench was dug. We set the route, depths and sleeves against those drawings, and the finishes were framed around the rough-in.

Get a quote

Tell us about your home or building

Choose your property type and what you need. Send the address and a few details, and we will reply with a fixed quote.

What do you need?
Exterior or label photos only. Please do not remove panel covers.