North Toronto Cabana
A backyard that does everything, on the existing 200 A service
An insulated cabana with a full kitchen and washroom, a louvered pergola, a gas fireplace, a water feature and three 4.5 kW infrared heaters. On paper it needed a bigger service. Two years of the home's own data said it didn't, so one cable from the house now runs the whole yard.
Plan My Outdoor Space →Prefer to talk? Call (416) 670-4030Fixed quote within 1 to 2 business days, sized on your own data.

The whole cabana, in three minutes

Filmed on site as each part went in: the power, the trench, the panel, the heaters, the fireplace, the lights and the fountain.
- 0:00Where the power comes from
- 0:26One trench for gas, water and power
- 0:37The cabana panel
- 1:50Recessed heaters, and the fan they need
- 2:02Pergola heaters under a thermal camera
- 2:28The gas fireplace on a GFI breaker
- 2:45Lights made for a slatted ceiling
- 2:52The fountain
Design: Bosque Landscape · Built by Parkscape · Film: Limeback Media · Heaters: Bromic · Electrical: Energable
North Toronto Cabana





A small building at the end of the garden
The landscape contractor designed the whole outdoor build, and had the electrical in the plan from day one. The cabana is really a small building: insulated walls, glass doors, its own kitchen, washroom, hot water and network. Outside it, a louvered-roof pergola, a gas fireplace, a fountain and landscape lighting.
Everything had to work from a phone, and none of the wiring could show. That meant every decision was made before the slat ceiling, the stone and the paving went on.
Six systems, one cabana panel
What each one draws, how it is wired, and the detail that makes it work. The bars compare each load with the cabana's 100 A panel.
Infrared heatersThree Bromic Platinum Smart-Heat Electric, 4.5 kW each
- How it is wired
- Two recessed flush into the cabana ceiling, one in the pergola beam. Each on its own 30 A circuit and an app-controlled dimmer.
- The detail
- The ceiling recess kits have their own cooling fans, so they get a separate, always-on circuit.
Cabana kitchenClear ice maker, fridge drawers, dishwasher drawer, counters
- How it is wired
- A dedicated circuit for every appliance, two 20 A counter circuits and one in the island, so the blender and kettle can run together.
- The detail
- A cabana kitchen gets used exactly like the one in the house.
Louvered pergolaMotorized louvered roof
- How it is wired
- The roof motor and its controller on their own circuit, with the controls kept out of the weather.
- The detail
- Motors and control hubs get constant power, never switched with a load.
Gas fireplaceElectric ignition and blower
- How it is wired
- Power is only for ignition and the blower: one receptacle inside the stone, fed by its own buried cable.
- The detail
- Ground-fault protection sits on a breaker in the cabana panel, where the reset is easy to find.
Water featureSubmersible fountain pump
- How it is wired
- Its own ground-fault protected circuit, a weatherproof switch and a service receptacle at the feature.
- The detail
- Water and power side by side is the one place nobody improvises.
Lighting and networkCeiling downlights, landscape lighting, TV and Cat6
- How it is wired
- Six slim black downlights on a dimmer in the slat ceiling, a circuit for the landscape lighting transformer, and a wired network run to the TV.
- The detail
- Wi-Fi in a backyard is never as good as you hope, so the cabana gets a cable.
165 A of new load, and no service upgrade
We pulled 17,400 hourly readings from Toronto Hydro, two full years, and ran the Code calculation before anything was designed.
Summer and winter never meet
Pick a season, then try the heater dimmers.
A cold evening outside, heaters on
Estimates from the load assessment, rounded.
One cable leaves the house, and everything hangs off it
Tap a system to see how it is wired.
Three 30 A heater circuits, plus a fan circuit
- Two ceiling heaters on a two-channel dimmer, the pergola heater on a one-channel dimmer
- Both dimmers in one dry equipment cavity, paired to a phone app
- A separate always-on circuit for the ceiling recess fans
The best electrical work disappears
All of this was built, inspected and then covered by the finishes. You can stand in the yard today and not find a single wire.

One trench
50 m of armoured copper in a sand bed, inspected, then buried under the paving for good.

The way out of the house
A weatherproof box on the foundation and a cored sleeve, sealed against weather outside and fire inside.

The heater dimmers
Both controllers in one dry, ventilated cavity, with clearance around their heat sinks.

The cabana panel
Every circuit labelled, with the ground-fault breakers where the owner will look for them.
The electrical list, in order
- Load assessment first. It decides whether you run a feeder or apply for a new service, and everything else waits on that answer.
- A real panel in the cabana. Every load gets its own breaker a few steps away, with room to grow.
- Trench once. Electrical, gas and water in one coordinated trench, planned with the landscape contractor before the first shovel.
- Heaters on dimmers, not switches. Comfort and load management in one device.
- Constant power for fans and controllers. Recess kits, roof motors and hubs are never switched with the load.
- Ground-fault protection you can reach. If a receptacle ends up behind a finish, protect it at the breaker.
- A wired network to the cabana. Backyard Wi-Fi is never as good as you hope.
- Leave spare circuits and a spare sleeve. The next idea always comes.
How a project like this comes together
- 1Site walk and plans. We walk the yard with the landscape drawings and list every load, drain, footing and heated zone.
- 2Load assessment. Two years of the home's utility data and the Code calculation confirm the service, before anything is designed.
- 3Route and trench layout. Feeder size, depths and sleeves set against the landscape plan, handed to the landscape crew to dig once.
- 4Feeder, panel and rough-in. Cable in, trench inspected before backfill, then every circuit roughed in before the finishes close.
- 5Connections and controls. Appliances, heaters and dimmers connected, apps paired and every circuit labelled.
- 6Inspection and handover. Final Electrical Safety Authority inspection, then a walkthrough of the controls with the owners.
Planning a cabana, pool house or outdoor kitchen?
Find out what your service can carry before you design
Send the address and your plans. We review your hourly data, check the service and send a fixed quote within 1 to 2 business days.
Get My Outdoor Quote →Outdoor Cabana Questions
The kind we would give before you commit a dollar of capital. Tap a question.
Does a backyard cabana with heaters and a kitchen need a service upgrade?
How do you power an outdoor cabana or pool house?
How much power do electric patio heaters use?
How deep does an outdoor feeder cable need to be buried in Ontario?
Should outdoor heaters be on switches or dimmers?
Who coordinates the electrical with the landscape contractor?
Get a quote
Tell us about your home or building
Choose your property type and what you need. Send the address and a few details, and we will reply with a fixed quote.